Through its verified, cross-referenced and up-to date entity reference data, Entity Plus helps institutions correctly identify their customers and counterparties as required, therefore helping them remaining compliant and providing reassurance that they are trustworthy. Manual Espanol Swift Elite 4. Open PDF Watch video. The full rundown on the Elite Direto Smart Trainer that'll be hitting stores very soon. Each manufacturer, advertiser, importer, or other entity (each, a “Listing Entity”) that is submitting listings or advertisements for publication in this.

• Installation Manual MMI-20020999, Rev AC May 2018 ® Micro Motion Compact Density Meter (CDM) 7835/7845 Liquid Density Meter Retrofit Installation. • Micro Motion employees. Micro Motion will not accept your returned equipment if you fail to follow Micro Motion procedures. Return procedures and forms are available on our web support site at www.emerson.com, or by phoning the Micro Motion Customer Service department. • Contents Contents Chapter 1 Planning..1 Retrofit installation overview..1 Installation checklist..1 Best practices..2 Pressure drop in the meter..3 Power requirements..5 Spacing requirements..9 Perform a pre-installation meter check.11 Chapter 2 Removing a 7835/7845 meter.12 Disconnect the 7835/7845 meter wiring.12 Remove the meter from the pipeline..14 Chapter 3. • Contents Micro Motion Compact Density Meter 7835/7845 Retrofit.

• Retrofit installation overview Following is an overview of the tasks required to install the Compact Density Meter (CDM) as a replacement to the Micro Motion 7835/7845 liquid density meter. We recommend that you review this information before beginning the retrofit installation. • Micro Motion provides safety barrier and galvanic isolator installation kits for wiring the CDM in a hazardous environment. These kits provide the appropriate barriers or isolators depending on the outputs available and approvals required. Contact flow.support@emerson.com for more information on ordering these kits.

• The pressure drop in the meter depends on the process conditions. The following figures illustrate the pressure drop for the meter at varying fluid density and viscosity. In addition, these charts show how the meter compares to the Micro Motion 7835/7845 liquid density meters. • Planning Figure 1-1: Sample pressure drop calculations (fluid viscosity equals 2 cP) Pressure drop (bar) Flow rate (m /hr) Note • Density = 800 kg/m • Viscosity = 2 cP Micro Motion Compact Density Meter 7835/7845 Retrofit. • Planning Figure 1-2: Sample pressure drop calculations (fluid viscosity equals 10 cP) Pressure drop (bar) Flow rate (m /hr) Note • Density = 800 kg/m • Viscosity = 10 cP Power requirements Following are the DC power requirements to operate the meter: •. • Planning Power cable recommendations for explosion-proof/flameproof meters Figure 1-3: Minimum wire gauge (AWG per feet ) 2 1.

6V 24 V 300ft 600ft 900ft 1200ft 1500ft 1800ft 2100ft 2400ft 2700ft 3000ft 91.44m 182.88m 274.32m 365.76m 457.2m 548.64m 640.08m 731.52m 822.96m 914.4m AWG maximum Distance of installation Micro Motion Compact Density Meter 7835/7845 Retrofit. • Planning Figure 1-4: Minimum wire area (mm per meter) 0.700 0.600 0.500 0.400 2 1.

6V 0.300 24 V 0.200 0.100 0. 00 0 10 0m 20 0m 30 0m 40 0m 50 0m 60 0m 70 0m 80 0m 90 0m 100 0m 328.084 ft. • Planning Power cable recommendations for intrinsically safe meters Figure 1-5: Minimum wire gauge (AWG per feet) 22. 8 V 24 V 3 0 0 6 0 0 9 0 0 12 0 0 1 50 0 18 0 0 21 0 0 24 0 0 27 0 0.

• Planning Figure 1-6: Minimum wire area (mm per meter) Minimum wire area (mm Distance of installation Spacing requirements When determining spacing requirements, be sure to consider the height requirements of the CDM in relation to the existing 7835/7845 meter (see Figure 1-8). • Planning Figure 1-7: CDM retrofit meter dimensions Dim. A — face to face is up to 40.4 inches (1026 mm) ± 0.125 in (3 mm) Nominal flow direction — the meter can be configured for normal (forward), reversed, or bi- directional flow 2x 1/2-14 NPT female electronic interface Note. • Visually inspect the meter for any physical damage. If you notice any physical damage to the meter, immediately contact Micro Motion Customer Support at flow.support@emerson.com. Position and secure the meter in a vertical position with the flow arrow pointing upward.

View and Download Aiwa NSX-A909 operating instructions manual online. CX-NA 909 Radio magnetocassette Iecteur de disques stereo SX-WNA909 Enceintes avant Telecommande Antenne:: 0::: c, Mode d’emploi, Avant de brancher Ie cordon secteur La tension nominale d’alimentation secteur. Aiwa NSX-A909 User Manual • General, Dolby nr, Copyright, Note, Caution • Aiwa Acoustics. Main unit CX-NA 909. FM tuner section. Tuning range. Manual Library / Aiwa. Aiwa NSX-A909. Mini HiFi System. Add a review. Type: Mini System. Formats: cd, tape, tuner. Components: CX-NA 909. Loudspeakers: SX-WNA909. Remote Control: RC-7AS08. Aiwa cx na909 remote control.

• Removing a 7835/7845 meter Removing a 7835/7845 meter Topics covered in this chapter: • Disconnect the 7835/7845 meter wiring • Remove the meter from the pipeline Disconnect the 7835/7845 meter wiring Prerequisites • Be prepared to manually record the existing wiring connections to the 7835/7845 meter. • Removing a 7835/7845 meter Figure 2-1: Standard electronics terminal locations Figure 2-2: Advanced electronics terminal locations Disconnect wiring from the meter. Installation Manual. • Removing a 7835/7845 meter Remove the meter from the pipeline Prerequisites Before you loosen or remove any connection, depressurize and drain the meter in accordance with the applicable codes of practice.